Tiling & Stone
QA inspection checklist
Tiling and stone installation quality audit.
Every check below carries what good looks like, when it passes, the standard it comes from and the defects that usually fail it. That guidance is what turns a tick-box into an inspection.
Substrate
- 1.Substrate flat and primedWhat to look forSubstrate (plaster, blockwork, screed, tile backer board) flat under 2 m straight edge. Suction primer applied to dusty/absorbent surfaces. Mechanical key for shiny surfaces. Substrate fully cured (typically 6+ weeks for new render/screed).Acceptable whenPer BS 5385-1 to 5: substrate flatness ±3 mm in 2 m straight edge for thin-bed adhesive; ±6 mm in 2 m for thick-bed. New render cured 14+ days, screed 6+ weeks before tiling. Primer per adhesive manufacturer's data sheet.StandardBS 5385-1:2018 — Wall and floor tiling — Ceramic, natural stone, terrazzo. BS 5385-3:2014 — Internal floor tiling. BS 5385-4 — Tiling in special conditions. TTA Manual.Common defectsTiles laid on uncured render — debonding within 6 monthsNo primer applied to dusty plaster — adhesive starves of moistureSubstrate not flat — > 6 mm in 2 m, lippage inevitablePlasterboard direct without tile backer in shower area — degradesSmooth render without mechanical key — adhesive slip
- 2.Tanking applied to wet areasWhat to look forTanking membrane (liquid-applied or sheet) covers floor of wet area, walls of shower zone to height of shower head + 200 mm. Continuous through all corners, around penetrations, lapped at joints. Pre-formed corner pieces and pipe collars used.Acceptable whenPer BS 5385-4 / NHBC: tanking to manufacturer's spec, AGREMENT/BBA certified. Wall tanking up to 1800 mm minimum or shower head + 200 mm. Continuous through corners with reinforcement strip. Pipe collars over all penetrations.StandardBS 5385-4:2015 — Tiling in special conditions. NHBC Standards 8.2. BBA / Agrément certificates for membranes.Common defectsTanking only on shower wall, not floor — water tracks under trayNo reinforcement strip at internal corners — splits with movementPipe collars omitted — sealant only used, failsTwo-part liquid tanking under-mixed — patchy cureTanking over silicone (incompatible) — debonds
Tile Installation
- 3.Tile type and colour match specWhat to look forTile model, dimension, colour, shade reference, surface finish (matt, polished, structured) match approved sample. Slip rating (R-class for floors) per spec — R10 minimum for general, R11/R12 for wet floors. Same shade batch ("calibre") across area.Acceptable whenTiles to BS EN 14411 — porcelain group BIa absorption ≤ 0.5%, ceramic group BIIa 0.5-3%. Slip resistance to DIN 51130 (R-class) or PTV ≥ 36 wet. Same shade and calibre within visual area.StandardBS EN 14411:2016 — Ceramic tiles. BS 5385 series. BS 7976-2 (slip). DIN 51130 (R-class).Common defectsMixed batch numbers — visible shade variation, "patchwork" effectCalibre mismatch — tiles slightly different size, joint grows or shrinks across areaR10 used in wet area where R11/R12 needed — slip claim riskGlazed (BII) tile used externally where porcelain (BIa) needed — frost crackingHoned/polished tiles in wet bathroom floor — slip hazard
- 4.Tiles level — lippage within toleranceRecord: Lippage (mm)What to look forLippage (vertical step at joint) within tolerance — feel with hand and check with straight edge. Diagonal sighting along walls picks up worst lippage. Levelling clip system in use on rectified large-format tiles.Acceptable whenPer BS 5385: lippage ≤ 1 mm for tiles up to 200 mm; ≤ 2 mm for larger tiles. For rectified large-format porcelain (≥ 600 mm), tighter — typically 1.5 mm max with levelling system. Floor flatness SR2 (±5 mm in 3 m) acceptable.StandardBS 5385-1, BS 5385-3. TTA Code of Practice. ISO 13007 (adhesives).Common defectsExcessive lippage > 2 mm — substrate not flat or adhesive not back-butteredLevelling clips not used on large-format tiles — tiles drop one sideCumulative joint drift — joints growing or shrinking across runLippage at edges/cuts where bedding inadequate
- 5.Joints consistentRecord: Joint width (mm)What to look forSpacers used during fixing. Joint width consistent across area — typically 2-3 mm for porcelain, 3-5 mm for ceramic, 5-10 mm for stone. Joints aligned (not staggered offset wrong way). No "running joint" creep.Acceptable whenJoint width per BS 5385 / TTA: minimum 2 mm for rectified porcelain, 3 mm for ceramic, 5 mm typical for stone. Tolerance ±0.5 mm. Joints straight in line with grid; offset patterns staggered as designed (50% or 33%, not random).StandardBS 5385 series. TTA Code of Practice.Common defectsVariable joint width across same wall — no spacers usedJoints < 1 mm — no allowance for thermal/moisture movementRandom offset on stagger pattern — looks chaoticCut tiles narrower than ½ at perimeter — visually unbalancedCumulative dimensional creep — at end of wall, last full tile is too wide
- 6.Adhesive coverage > 95%What to look forTap test reveals no hollow spots. Lift sample tile during install — adhesive coverage on back evaluated visually. Notched trowel direction perpendicular to short edge of tile (combs squashed during pressing). Back-buttered for large format.Acceptable whenPer BS 5385: ≥ 80% solid bedding for internal walls (dry areas), ≥ 95% for floors and wet walls. External and large-format ≥ 100% (full bed, back-buttered). Adhesive class C2 (improved cementitious) typical, S1/S2 (deformable) for UFH/heated.StandardBS 5385 series. BS EN 12004:2017 — Adhesives for tiles. BS EN 12002:2008 (deformability).Common defectsHollow tiles tap test — combs not squashed, < 95% coverageNo back-buttering on large format — only ridges of adhesive contactingClass C1 used over UFH where S1/S2 deformable specifiedAdhesive skinned over before tile placed — bond failsNotch direction wrong — air channels trapped
Grouting & Finishing
- 7.Grout joints full and consistentWhat to look forGrout fills joint to depth ≥ 2/3 of tile thickness. Tooled flush with tile face (or slightly below for textured tiles). No voids or pinholes. Grout fully cured before silicone applied. Colour consistent — mixed in single batch where possible.Acceptable whenPer BS 5385 / BS EN 13888: grout fills joint to within 1-2 mm of tile face. Cementitious CG2 standard, RG (epoxy reaction resin) for chemical/heavy duty. Joint depth fill ≥ 2/3 tile thickness.StandardBS EN 13888:2008 — Grouts for tiles. BS 5385 series. TTA Code of Practice.Common defectsPinholes/voids in grout — surface set before troweled in fullyJoint depth shallow — water enters and lifts grout outColour banding — multiple batches mixed differently (water content)Cement grout in chemical/food prep area where epoxy neededGrouting before adhesive cured — solvent vapour locks grout
- 8.Silicone at movement joints and perimeterWhat to look forSilicone (sanitary grade with mould inhibitor) at all internal corners, perimeter (wall/floor, wall/ceiling), around baths, basins, shower trays. Backer rod where joint > 6 mm. Tooled smooth. No grout at these joints.Acceptable whenSanitary silicone to BS EN 15651-3 type S (sanitary). Joint depth ≥ ½ width, max width 12 mm. Backer rod for joints > 6 mm. Application per BS 6213.StandardBS 5385-4. BS EN 15651-3:2017 — Sealants for sanitary joints. BS 6213:2000 — Sealing joints in buildings.Common defectsGrout used at internal corners instead of silicone — cracks with thermal movementSanitary silicone without mould inhibitor — black mould within monthsSilicone tooled too thin — bond stress, splitsSilicone over wet substrate — fails to cureNo backer rod in deep joint — silicone three-sided adhesion, splits
- 9.Tiles clean and free from residueWhat to look forTile surface clean, no grout haze. Polished/honed surfaces specifically — no acid residue or etching from acid wash. Inspect under raking light for hairline scratches. Sealant applied where required (natural stone, unglazed porcelain).Acceptable whenFinal clean per BS 5385 / TTA: tiles to be free from grout, adhesive, sealant residues. Acid clean (where used) neutralised with sodium bicarbonate. Penetrating sealer applied to absorbent stone (granite, limestone) per supplier.StandardBS 5385 series. TTA Code of Practice. Stone Federation guidance.Common defectsGrout haze visible under raking light — final buff missedAcid clean on marble/limestone — etching, no longer polishedStone unsealed — staining within first weeks of useCement residue not removed before grout curedDamage from follow-on trades — bath or shower screen scratches tiles
Questions people ask
What is a tiling & stone QA inspection for?
To record that the work was checked against the specification before it was covered up or handed over: a pass or fail against each item, a measurement where one matters, and a photo where it failed. It is the evidence a client's quantity surveyor or clerk of works asks for, and the thing that settles the argument at final account.
What standards does this checklist check against?
Each item names its reference. On this checklist that includes BS 5385-1:2018, BS 5385-4:2015, BS EN 14411:2016, BS 5385-1, BS 5385 series. TTA Code of Practice., BS 5385 series. BS EN 12004:2017. The contract specification and the approved drawings always take precedence over a general standard; where they say something stricter, inspect to that.
Who signs a QA inspection off?
The person who carried out the check, named and dated, and where the contract calls for it the client's representative as a witness. The signature records that the check was done and what was found. It is not a warranty of the work.
How many items are on it, and do I have to use them all?
9 checks across 3 sections. Delete what does not apply to the job and add anything the specification asks for that is not here. A checklist that has plainly been thought about carries more weight than a long one nobody read.
Is this useful for a subcontractor as well as a main contractor?
More so. The subcontractor is the one who gets asked to come back and open something up. A signed inspection sheet with photos at the time is the cheapest insurance on a construction site.
Run this inspection on a phone
The same 9 checks, with the guidance a tap away, photos against each fail, measurements recorded, an NCR raised automatically and a branded PDF at the end. Signed on site. 14 days free.
Start free trial